ENERGYMASTERTM MAKEUP AIR
EQUIPMENT
- INEXPENSIVELY CONVERTS ANY EXISTING MAKE-UP AIR SYSTEM
- SHUTS OFF THE BURNERS
- UTILIZES THE WASTED HEAT AT THE CEILING
EnergyMasterTM make-up air conversion units
with the patented SeasonMaster® (Patent
No. 5,111,739) hot/cold weather air direction controller will convert any size fired make-up air equipment to our unfired system. It uses all of your building’s stratified wasted heat before any additional fuel is burned. The air is better circulated throughout the workplace. After being converted, most fired make-up air unit burners do not fire at all!
View an Animated DEMO Now
Testimonial Success Of Our Clients Using EnergyMasterTM
Average Return On Investment: ½ To 1 ½ Heating Seasons
EnergyMaster’s installed cost is substantially less than the cost of a fired make-up air system and will return its investment within one and one half heating seasons or less.
Over 3500 Systems Installed Nationally in
Plants From Automotive, General Manufacturing, and Commercial Product
ELIMINATE or CONTROL:
Negative Air Pressure on Throughout Entire Plants / Factories.
EnergyMasterTM brings outside make-up air into a building through its unique distribution duct system. And the EnergyMasterTM system can include up to 700 ft. of distribution ducting. It uses up to 100% of the stratified heat at the ceiling which is otherwise wasted when it is lost through the roof.
-
Carbon Monoxide, Welding Smoke, Fumes, Mist, Dust, Odor -- EnergyMasterTM controls or replaces plant air contaminants while exhausting them outside. Low velocity fresh air remains circulating throughout the workspace. The most direct method is utilized so a minimal amount of CFM is used to control these air contaminants
-
Dead Air Spots
-
Overheated Floor Areas.
-
Inexpensively moves excessive objectionable heat up to 700 ft., to distant areas that can use it.
-
Cold, Drafty Floors
-
Other Indoor Air Quality / Ventilation Problems
REDUCE MAKEUP AIR FUEL BILLS UP TO 100%
When the air delivery holes are positioned for winter operation, EnergyMasterTM evenly distributes the outside air upward, blending it with the stratified hot air at the ceiling. This mixing action tempers the incoming make-up air without using additional fuel.
|
COOLS IN SUMMER
When the air delivery holes are positioned for summer operation, EnergyMasterTM evenly distributes the cooler outside air toward the floor. This keeps the objectionable hot air stratified at the ceiling and delivers the cooler outdoor air downward towards the floor.
Roof & Wall Make-Up Air
Units Available.
EnergyMasterTM's Configuration Can Easily be Changed Simply & Quickly from the Plant Floor. Manual or Motorized Remote
Control Available. |
EASILY MAINTAINED – QUICKLY CHANGE BETWEEN HOT AND COLD WEATHER OPERATION
Previously many man hours were required to rotate the ducts each season. Now the patented SeasonMasterTM floor operated air direction controller allows quick duct position changes between the hot and cold weather air delivery positions, no matter how often the outdoor temperatures demand it.
NOTE:- During hot weather the air holes must be positioned downward to prevent the stratified ceiling heat from being forced down to the floor thereby overheating the workspace.
ADDITIONAL ENERGYMASTERTM MAKE-UP AIR SYSTEM BENEFITS
-
More Comfortable and Productive Employees
-
Helps Meet Clean Air Regulations Inexpensively.
When EnergyMasterTM evenly distributes outside make-up air throughout a building in conjunction with an adequate exhaust system, it uses the minimum amount of outside make-up air possible to reduce the air contamination concentration (PPM) to an acceptable level.
-
Air Contaminants Controlled With Less Exhaust Air.
EnergyMasterTM strategically delivers make-up air throughout your plant in relation to the contamination source. Therefore, the amount of air exhausted can be significantly reduced while maintaining clean air conditions. For example, in northern Ohlo and southern Michigan, each 1000 cubic feet of exhaust air reduced, provides a savings of 25,000 to 50,000 BTU’s per hour.
top
Sample Pricing for EnergyMasterTM
What Our Make-Up Air Equipment Customers Are Saying About EnergyMasterTM
“the SeasonMasterTM has eliminated the employee complaints of being “too hot” or “too cold”, especially in between seasons”
Complete Letter
Glenn W. Watkins
Plant Engineer, ArvinMeritor (formerly Rockwell Automotive) 
“To customers who ask about maintenance, I say that if any product were more maintenance free it would have no moving parts”
Complete Letter
Larry Milam
Manager of Engineering, Shaw Industries 
You’ll Improve Your Make-Up Air Heating and Cooling System With Our Indoor Air Control Systems Technology - Guaranteed
Free Evaluation of Your Unique Situation. We Have a Package to Fit Your Requirements
|